Note

This documentation is for a prior release of Kinetica. For the latest documentation, click here.

Clear Table Monitor

Deactivates a table monitor previously created with Create Table Monitor.

Input Parameter Description

NameTypeDescription
topic_idstringThe topic ID returned by Create Table Monitor .
optionsmap of string to strings

Optional parameters. The default value is an empty map ( {} ).

Supported Parameters (keys)Parameter Description
keep_autogenerated_sink

If true, the auto-generated datasink associated with this monitor, if there is one, will be retained for further use. If false, then the auto-generated sink will be dropped if there are no other monitors referencing it. The default value is false. The supported values are:

  • true
  • false
clear_all_references

If true, all references that share the same input parameter topic_id will be cleared. The default value is false. The supported values are:

  • true
  • false

Output Parameter Description

NameTypeDescription
topic_idstringValue of input parameter topic_id.
infomap of string to stringsAdditional information.